Other part numbers |
02355SDP (CE8865-SAN-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) 02355SDR (CE8865-SAN-4C Mainframe (With 4 Subcard Slots, 2*AC Power Module, 3*Fans, Port-side Exhaust)) |
Installation Type |
Cabinet installation |
Depth [mm] |
600.0 mm |
Chassis height [U] |
2 |
Wide [mm] |
442.0 mm |
Height [mm] |
88.1 mm |
Weight with packaging [kg(lb)] |
21.3 kg (46.96 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels) 24.02 kg (52.96 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards) |
Weight without packaging [kg(lb)] |
12.76 kg (28.13 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules, cards, and card filler panels) 15.48 kg (34.13 lb) (with four card filler panels, two power module filler panels, and three fan module filler panels but no power modules, fan modules, and cards) |
Maximum power consumption [W] |
Configured with four CE88-SAN-D16CQ-H cards: - 888 W (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules) - 1318 W (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules) - 1376 W (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules) Configured with four CE88-SAN-D26F-H cards: - 410 W (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules) - 718 W (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules) |
Typical power consumption [W] |
Configured with four CE88-SAN-D16CQ-H cards: - 650 W (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules) - 728 W (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules) Configured with four CE88-SAN-D26F-H cards: - 305 W (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) - 338 W (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Static power consumption [W] |
Configured with four CE88-SAN-D16CQ-H cards: 569 W Configured with four CE88-SAN-D26F-H cards: 276 W |
Heat dissipation mode |
Air cooling |
Maximum heat dissipation [BTU/hour] |
Configured with four CE88-SAN-D16CQ-H cards: - 3029.9 BTU/hour (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal temperature, dual AC power modules) - 4497 BTU/hour (100% traffic load, long-distance optical modules on 64 x 100GE ports, high temperature, dual AC power modules) - 4694.9 BTU/hour (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports, high temperature, dual AC power modules) Configured with four CE88-SAN-D26F-H cards: - 1398.9 BTU/hour (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules) - 2449.8 BTU/hour (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules) |
Typical heat dissipation [BTU/hour] |
Configured with four CE88-SAN-D16CQ-H cards: - 2217.8 BTU/hour (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual AC power modules) - 2483.9 BTU/hour (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC power modules) Configured with four CE88-SAN-D26F-H cards: - 1040.7 BTU/hour (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) - 1153.3 BTU/hour (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) |
Static heat dissipation [BTU/hour] |
Configured with four CE88-SAN-D16CQ-H cards: 1941.4 BTU/hour Configured with four CE88-SAN-D26F-H cards: 941.7 BTU/hour |
Power supply mode |
AC pluggable,DC pluggable,HVDC pluggable |
Rated input voltage [V] |
- 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 1800 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 2000 W high-voltage DC power module: 336 V DC - 2200 W DC power module: –48 V DC to –60 V DC; +48 V DC |
Input voltage range [V] |
- 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC - 1800 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC - 2000 W high-voltage DC power module: 260 V DC to 400 V DC - 2200 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC |
Maximum input current [A] |
- 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 1800 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 2000 W high-voltage DC power module: 10 A (336 V DC) - 2200 W DC power module: 63 A (–48 V DC to –60 V DC); 63 A (+48 V DC) |
Rated output power [W] |
- 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V AC) - 1800 W AC&240 V DC power module: 1800 W (200 V AC to 240 V AC&240 V DC), 900 W (100 V AC to 130 V AC) - 2000 W high-voltage DC power module: 2000 W - 2200 W DC power module: 2200 W |
Memory |
DRAM: 8 GB |
NOR Flash |
64 MB x 2 |
SSD Flash |
4GB SSD |
USB |
It can be used for log backup and USB-based deployment. This function is reserved. |
Console port |
RJ45 |
Downlink Service interface |
For details, see the port description of each card. |
Uplink Service interface |
For details, see the port description of each card. |
Service port supporting the stack function |
Reserved function. This function is not enabled. |
RTC |
Supported |
Switching capacity [bps,bit/s] |
To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. |
Redundant fans |
The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply |
1+1 backup |
Number of power modules |
2 |
Power supply surge protection |
- AC: 6 kV in common mode and 6 kV in differential mode - HVDC: 4 kV in common mode and 2 kV in differential mode - DC: 4 kV in common mode and 2 kV in differential mode |
Types of fans |
Pluggable |
Number of fans |
3 |
Airflow direction |
Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and power modules must have the same airflow direction. |
Storage temperature [°C(°F)] |
-40ºC to +70ºC (-40°F to +158°F) |
Long-term operating temperature [°C(°F)] |
0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH] |
5% to 95% RH, non-condensing |
Long-term operating relative humidity [RH] |
5% RH to 95% RH, non-condensing |
Storage altitude [m(ft.)] |
≤ 5000 m (16404 ft.) |
Long-term operating altitude [m(ft.)] |
≤ 5000 m (16404 ft.) |
MTBF [year] |
48.4 years |
MTTR [hour] |
1.86 hours |
Noise at high temperature (40°C, sound pressure) |
Port-side air intake: < 86.1 dB(A) Port-side air exhaust: < 87.9 dB(A) |
Noise at normal temperature (27°C, sound pressure) |
Port-side air intake: < 64.3 dB(A) Port-side air exhaust: < 65.2 dB(A) |
Availability |
0.9999964621 |