Communication Mode: | Full-Duplex & Half-Duplex |
---|---|
Type: | Ethernet Switch |
Transmission Rate: | 10/100/1000Mbps |
Still deciding? Get samples of US$ 13000/piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Specification | ||||||
Physical specifications | Dimensions (W x D x H): 442 mm x 1065 mm x 1597.4 mm (17.40 in. x 41.93 in. x 62.89 in. (36U)) | ||||||
Depth from fan module handles to the lower enclosure frame: 1065 mm (41.93 in.) | |||||||
Depth from fan module handles to the air filter door: 1085 mm (42.72 in.) | |||||||
Weight | |||||||
Empty: 221.6 kg (488.54 lb) | |||||||
Fully loaded: 474 kg (1044.99 lb) | |||||||
Environment parameters | Temperature | Operating temperature: 0°C to 40°C (32°F to 104°F) at an altitude between 0 m and 1800 m (0 ft. and 5906 ft.) | |||||
NOTE: | |||||||
When the altitude is between 1800 m and 4000 m (5906 ft. and 13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). | |||||||
Storage temperature: -40°C to +70°C (-40°F to +158°F) | |||||||
Relative humidity | 5% RH to 85% RH, noncondensing | ||||||
Altitude | < 4000 m (13123 ft.) | ||||||
Noise (27°C) | ≤ 78 dBA | ||||||
Power specifications | Power port | The power modules are plug-and-play. Power cables are connected to sockets on the power distribution unit at the rear of the chassis. | |||||
AC power input | Rated voltage: 110 V AC/220 V AC; 50 Hz/60 Hz | ||||||
Rated voltage range: 100 V AC to 120 V AC/200 V AC to 240 V AC | |||||||
Maximum voltage range: 90 V AC to 290 V AC; 45 Hz to 65 Hz (PAC-2700WA)/47 Hz to 63 Hz (PHD-3000WA) | |||||||
Maximum input current | |||||||
Using PAC-2700WA power modules: 16 A | |||||||
Using PHD-3000WA power modules: 18.5 A | |||||||
DC power input | Rated voltage: -48 V DC/-60 V DC | ||||||
Maximum voltage range: -40 V DC to -72 V DC | |||||||
Rated input current: 50 A @ -48 V DC | |||||||
Maximum input current: 62 A @ -40 V DC | |||||||
High-voltage DC power input | Rated voltage: 240 V DC | ||||||
Rated voltage range: 188 V DC to 288 V DC | |||||||
Maximum output power of AC power modules | Using PAC-2700WA power modules: | ||||||
380 V three-phase AC input, 220 V single-phase AC input, or 110 V dual-live-wire AC input: | |||||||
N+N backupc (N ≤ 10): 2700 W x 10 = 27000 W | |||||||
N+1 backup and N+0 mode (N ≤ 11): 2700 W x 11 = 29700 W | |||||||
110 V single-live-wire AC input: | |||||||
N+1 backup (N ≤ 19): 1200 W x 19 = 22800 W | |||||||
N+0 mode (N ≤ 20): 1200 W x 20 = 24000 W | |||||||
Using PHD-3000WA power modules: | |||||||
380 V three-phase AC input, 220 V single-phase AC input, or 110 V dual-live-wire AC input: | |||||||
N+N backup, N+1 backup, and N+0 mode (N ≤ 10): 3000 W x 10 = 30000 W | |||||||
110 V single-live-wire AC input: | |||||||
N+1 backup (N ≤ 19): 1500 W x 19 = 28500 W | |||||||
N+0 mode (N ≤ 20): 1500 W x 20 = 30000 W | |||||||
NOTE: | |||||||
If the power modules use a 110 V power source, follow these suggestions: | |||||||
Use double live wires. In this case, the output power of a power module is 2700 W/3000 W. | |||||||
If only one live wire is used, the output power of a power module is 1200 W/1500 W. In this case, it is recommended that you use more power modules or change the power module backup mode to increase the output power. | |||||||
Maximum output power of DC power modules | N+N backupc (N ≤ 10): 2200 W x 10 = 22000 W | ||||||
N+1 backup and N+0 mode (N ≤13): 2200 W x 13 = 28600 W | |||||||
Maximum output power of high-voltage DC power modules | N+N backup, N+1 backup, and N+0 mode (N ≤ 10): 3000 W x 10 = 30000 W | ||||||
Heat dissipation | The power modules have their own fans, which cool the power modules through front-to-back airflow. | ||||||
Hot swap | The power modules are hot swappable. | ||||||
Reliability and availability | Modules | Power module: | |||||
If double external power supply systems are used, the N+N backup mode is recommended. | |||||||
If a single external power supply system is used, you can use more power modules or change the power module backup mode to increase the output power. To enhance system reliably, you are advised to use the N+1 backup mode. | |||||||
Fan module: Fan modules work in hot backup mode. At normal temperature range, the system can operate normally for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. | |||||||
MPU: 1:1 hot standby | |||||||
CMU: 1:1 hot standby | |||||||
Hot swap: All the power modules, fan modules, and cards support hot swap. | |||||||
Chassis | Mean Time Between Failures (MTBF): 32.00 years | ||||||
Mean time to repair (MTTR): 1 hour | |||||||
Availability: 0.9999964326 | |||||||
NOTE: | |||||||
The preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on the modules configured in the equipment. | |||||||
Technical specifications | Maximum port density | V100R003C00 and V100R003C10: 64x100GE, 384x40GE, 1536x10GEa, or 768xGE | |||||
V100R005C00 and V100R005C10: 192x100GE, 384x40GE, 1536x10GEa, or 768xGE | |||||||
V100R006C00: 192x100GE, 576x40GE, 2304x10GEa, or 768xGE | |||||||
V200R001C00, V200R002C50, and V200R003C00: 576x100GE, 576x40GE, 2304x25GEb, 2304x10GEa, or 768xGE | |||||||
Certification | Safety standards compliance | ||||||
EMC standards compliance | |||||||
Environmental standards compliance |
Chongqing Chimu Technology Co., Ltd. was established in 2011, we have been engaged in this industry 11 years. Relying on 11 years of deep experience in the communication field and scientific and technological innovation ability, through the integration of multi-brand, full series of communication products resources, with a one-stop service model. Let the network better connect you and me, connect the world. In order to meet the needs of customers, we have eatablished a perfect supply chain system to provide super products with reliable quality and reasonable price.
We are devoted to offering Switches, Routers, Servers, Storages, LTs, SDHs, Network Modules, Interface Cards, Security Firewalls, Wireless AP. Our long-term aim is to provide users high-quality, efficient, economic, timely services. Looking forward to establish long-term and win-win business relations with you.
A)Stable and Wide Supply Chain System
we have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
B)Competitive Price
We ensure the most competitive price. Warm reminders here, telecommunications equipment configuration is quite different, the price shown on the website is only for reference. After configuration and quantity been confirmed, we will give the final most competitive discounted price.
C) Safe and Easy Payment Solutions
We accept all major credit cards, PayPal and wire transfer.
D)Fast Delivery and Shipping
Fast, professional and reliable delivery.
E)11 +Years Experience
we have been engaged in this industry more than 11 years, we have rich industry experience.
Q: How about your main products?
A: Our product lines include Switches, Routers, SFP Modules, OLTs, SDHs, Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Q: What brand of products do you offer?
A: We can supply all the brands you need.
Q: what services can we provide?
A:Accepted Delivery Terms: FOB,CFR,EXW,FCA;
Accepted Payment Currency:USD,EUR,CAD,HKD,GBP,CNY;
Accepted Payment Type: T/T,MoneyGram,PayPal,Western Union,Cash etc...
Q: Can we get free samples?
A: Sorry, it is not available, but you can pay for one.
Q. How can we guarantee quality?
A:Always a pre-production sample before mass production;
Always final Inspection before shipment;
Q: How about your delivery time?
A: Generally, it will take 1 to 10 days after receiving your deposit. The specific delivery time depends on the items and the quantity of your order.
Q: Do you test all your goods?
A: Yes, We have professional engineer to test all devices before shipping.
Q:How about the MOQ?
A:1 piece