Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W

Product Details
Communication Mode: Full-Duplex & Half-Duplex
Type: Ethernet Switch
Transmission Rate: 10/100/1000Mbps
Still deciding? Get samples of US$ 1000/piece
Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
21
Year of Establishment
2011-01-13
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
  • Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
  • Our Advantages
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
CloudEngine 16804
Ports
None
Transport Package
Cartons
Specification
730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x
Origin
China
HS Code
8517623200
Production Capacity
5000PCS/Month

Product Description

 

Product Description

Slot Type Slot ID Slot Direction Remarks
LPU slot Slots 1 to 4 The top of the board faces upwards Different types of LPUs can be installed in the same chassis.
MPU slot Slots 5 and 6 The top of the board faces upwards

Two MPUs work in active/standby mode for 1:1 hot standby.

By default, the MPU with a smaller slot ID is the active MPU, and the MPU with a larger slot ID is the standby MPU.

SFU slot Slots 1 to 9 (Slots 1, 2, and 9 cannot be used.) The right side of the board faces upwards SFUs work in load balancing and redundancy mode. SFUs in the same chassis must be the same model. That is, SFUs of different models cannot be installed in the same chassis.
PM slot Slots 1 to 6 The indicator light end upwards PMs are plug-and-play.
Fan module slot Slots 1 to 3 The indicator light end upwards At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.

Detailed Photos

Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W

1. Chassis header

2. Front ESD jack

3. PM

4. Power switch

5. MPU

6. LPU

7. Cable management frame

8. PEM

9. Fan module

10. SFU

SFUs are located behind fan modules and are invisible after all fan modules are installed.

11. Location of fan modules and SFUs

12. Two ground points for a two-hole OT terminal

There is a yellow grounding label attached.

13. SFU wrench

14. Rear ESD jack

15. Assembly chassis bar code

16. Serial number label

17. MAC address label

-

-

-

Item Specification
Dimensions with packaging (H x W x D) [mm (in.)] 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.)
Dimensions without packaging (H x W x D) [mm (in.)] 438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including mounting brackets)
Weight without packaging [kg (lb)] 94.1 kg (207.49 lb) (including two MPUs and filler panels)
Weight without packaging (full configuration) [kg (lb)] 162 kg (357.21 lb)
Weight with packaging [kg (lb)] 138 kg (304.29 lb)
Cabinet installation standards A812
Chassis height [U] 9.8 U
Redundant MPUs 1:1
Redundant Switch fabrics N+M
Power supply mode
  • AC
  • HVDC
Number of power modules 6
Redundant power supply
  • Dual-input power supply system: N+1 backup is recommended.
  • Single-input power supply system: N+1 backup

Dual-input power supply is recommended to ensure reliability.

Rated input voltage [V]
  • AC: 220 V; 50 Hz/60 Hz
  • High-voltage DC (HVDC): 240 V/380 V
Input voltage range [V]
  • AC: 176-290 V; 45-65 Hz
  • High-voltage DC (HVDC): 188 V to 288 V or 260 V to 400 V
Maximum input current [A]
  • AC: 16 A @ 200 V; 18.5 A @ 176 V
  • High-voltage DC (HVDC): 18 A @ 188 V; 13 A @ 260 V
Maximum output power [W]
  • In 5+1 backup mode: 3000 W x 5 = 15000 W
  • In 6+0 backup mode: 3000 W x 6 = 18000 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Redundant fans Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Heat dissipation using fans
Airflow direction Front-to-back airflow
Availability 0.9999971695
MTBF [year] 34.93 year
MTTR [hour] 1 hour
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).)
Long-term operating relative humidity [RH] 5% RH to 85% RH, noncondensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F)
Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)

Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W

  

Product Parameters

 
Item Specification
Dimensions with packaging (H x W x D) [mm (in.)] 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.)
Dimensions without packaging (H x W x D) [mm (in.)] 438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including mounting brackets)
Weight without packaging [kg (lb)] 98.1 kg (216.31 lb) (including two MPUs and filler panels)
Weight without packaging (full configuration) [kg (lb)] 163.6 kg (360.74 lb)
Weight with packaging [kg (lb)] 142 kg (313.11 lb)
Cabinet installation standards A812
Chassis height [U] 9.8 U
Redundant MPUs 1:1
Redundant Switch fabrics N+M
Power supply mode DC
Number of power modules 6
Redundant power supply
  • Dual-input power supply system: N+1 backup is recommended.
  • Single-input power supply system: N+1 backup

Dual-input power supply is recommended to ensure reliability.

Rated input voltage [V] -48 V/-60 V
Input voltage range [V] -40 V to -72 V
Maximum input current [A] 58.5 A for the voltage of -40 V
Maximum output power [W]
  • In 5+1 backup mode: 2200 W x 5 = 11000 W
  • In 6+0 backup mode: 2200 W x 6 = 13200 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Redundant fans Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Heat dissipation using fans
Airflow direction Front-to-back airflow
Availability 0.9999971695
MTBF [year] 34.93 year
MTTR [hour] 1 hour
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).)
Long-term operating relative humidity [RH] 5% RH to 85% RH, noncondensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F)
Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)

Company Profile

  Chongqing Chimu Technology Co., Ltd. was established in 2011, we have been engaged in this industry 11 years.   Relying on 11 years of deep experience in the communication field and scientific and technological innovation ability, through the integration of multi-brand, full series of communication products resources, with a one-stop service model.  Let the network better connect you and me, connect the world.  In order to meet the needs of customers, we have eatablished a perfect supply chain system to provide super products with reliable quality and reasonable price. 
  We are devoted to offering Switches,  Routers,  Servers, Storages, LTs,  SDHs,  Network Modules,  Interface Cards,  Security Firewalls, Wireless AP. Our long-term aim is to provide users high-quality, efficient, economic, timely services.  Looking forward to establish long-term and win-win business relations with you.

Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W
Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W

Our Advantages

A)Stable and Wide Supply Chain System
we have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
B)Competitive Price
We ensure the most competitive price. Warm reminders here, telecommunications equipment configuration is quite different, the price shown on the website is only for reference. After configuration and quantity been confirmed, we will give the final most competitive discounted price.
C) Safe and Easy Payment Solutions
We accept all major credit cards, PayPal and wire transfer.
D)Fast Delivery and Shipping
Fast, professional and reliable delivery.
E)11 Years Experience
we have been engaged in this industry more than 11 years, we have rich industry experience.

Packaging & Shipping

Cloudengine 16804 Assembly Chassis CE16804-Ah CE16804-DC 02352rcu 02352rcr for H W

FAQ

Q: How about your main products?
A: Our product lines include Switches, Routers, SFP Modules, OLTs, SDHs, Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.

Q: What brand of products do you offer?
A: We can supply all the brands you need.

Q: what services can we provide?
A:Accepted Delivery Terms: FOB,CFR,EXW,FCA;
   Accepted Payment Currency:USD,EUR,CAD,HKD,GBP,CNY;
   Accepted Payment Type: T/T,MoneyGram,PayPal,Western Union,Cash etc...

Q: Can we get free samples?
A: Sorry, it is not available, but you can pay for one.

Q. How can we guarantee quality
?

A:Always a pre-production sample before mass production;
   Always final Inspection before shipment;

Q: How about your delivery time?
A: Generally, it will take 1 to 10 days after receiving your deposit.  The specific delivery time depends on the items and the quantity of your order.

Q: Do you test all your goods?
A: Yes, We have professional engineer to test all devices before shipping.

Q:How about the MOQ?
A:1 piece



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier