Item |
Specification |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 88.1 mm x 442.0 mm x 600.0 mm (3.47 in. x 17.40 in. x 23.62 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 88.1 mm x 442.0 mm x 640.0 mm (3.47 in. x 17.40 in. x 25.20 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
280.0 mm x 875.0 mm x 665.0 mm (11.02 in. x 34.45 in. x 26.18 in.) |
Chassis height [U] |
2 U |
Chassis material |
Metal |
Weight without packaging [kg(lb)] |
20.50 kg (45.19 lb) |
Weight with packaging [kg(lb)] |
26.82 kg (59.13 lb) |
Typical power consumption [W] |
Configured with four XSIC-C16H000 cards: 940 W |
Configured with four XSIC-L16Q000 cards: 724 W |
Configured with four XSIC-C10H000 cards: 508 W |
Configured with four XSIC-D12B000 cards: 621 W |
Configured with four XSIC-Y26B000 cards: 423 W |
Configured with four XSIC-X26B000 cards: 366 W |
Typical heat dissipation [BTU/hour] |
Configured with four XSIC-C16H000 cards: 3207.37 BTU/hour |
Configured with four XSIC-L16Q000 cards: 2470.36 BTU/hour |
Configured with four XSIC-C10H000 cards: 1733.35 BTU/hour |
Configured with four XSIC-D12B000 cards: 2118.91 BTU/hour |
Configured with four XSIC-Y26B000 cards: 1433.32 BTU/hour |
Configured with four XSIC-X26B000 cards: 1248.83 BTU/hour |
Maximum power consumption [W] |
Configured with four XSIC-C16H000 cards: |
- 1306 W (two 2000 W AC power modules, 220 V input) |
Configured with four XSIC-L16Q000 cards: |
- 1138 W (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-C10H000 cards: |
- 832 W (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-D12B000 cards: |
- 1078 W (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-Y26B000 cards: |
- 796 W (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-X26B000 cards: |
- 788 W (two 1200 W AC power modules, 110 V input) |
Maximum heat dissipation [BTU/hour] |
Configured with four XSIC-C16H000 cards: |
- 4456.20 BTU/hour (two 2000 W AC power modules, 220 V input) |
Configured with four XSIC-L16Q000 cards: |
- 3882.97 BTU/hour (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-C10H000 cards: |
- 2838.87 BTU/hour (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-D12B000 cards: |
- 3678.24 BTU/hour (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-Y26B000 cards: |
- 2716.03 BTU/hour (two 1200 W AC power modules, 110 V input) |
Configured with four XSIC-X26B000 cards: |
- 2688.73 BTU/hour (two 1200 W AC power modules, 110 V input) |
Static power consumption [W] |
Configured with four XSIC-C16H000 cards: 593 W |
Configured with four XSIC-L16Q000 cards: 539 W |
Configured with four XSIC-C10H000 cards: 295 W |
Configured with four XSIC-D12B000 cards: 299 W |
Configured with four XSIC-Y26B000 cards: 259 W |
Configured with four XSIC-X26B000 cards: 259 W |
MTBF [years] |
48.4 years |
MTTR [hours] |
2 hours |
Availability |
> 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
86.1 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] |
74.1 dB(A) |
Number of card slots |
4 |
Number of power slots |
2 |
Number of fans modules |
3 |
Redundant power supply |
1+1 |
Long-term operating temperature [°C(°F)] |
-5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5906 ft.) |
When the QSFP-100G-ZR4 or QSFP-DD-400G-LR8 optical modules are configured, the operating temperature ranges from -5°C to +40°C (23°F to 104°F). |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Devices cannot start when the temperature is lower than 0°C (32°F). |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
Pluggable power supply |
Rated input voltage [V] |
AC input: 100 V AC to 240 V AC; 50/60 Hz |
High-voltage DC input: 240 V DC |
DC input: -48 V DC to -60 V DC |
Input voltage range [V] |
AC input: 90 V AC to 290 V AC; 45-65 Hz |
High-voltage DC input: 190 V DC to 290 V DC |
DC input: -38.4 V DC to -72 V DC |
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory |
8 GB |
Flash memory |
Physical space: 4 GB |
Console port |
RJ45 |
Eth Management port |
RJ45 |
USB |
Supported |
RTC |
Supported |
RPS input |
Not supported |
Power supply surge protection [kV] |
Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode |
Ingress protection level (dustproof/waterproof) |
IP20 |
Types of fans |
Pluggable |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction |
Air intake from front, air exhaustion from rear (front-to-rear) |
PoE |
Not supported |
Certification |
EMC certification |
Safety certification |
Manufacturing certification |