Still deciding? Get samples of $ !
Request Sample
|
| Type: | Hua Wei Router |
|---|---|
| Network Site: | Border Router |
| Transfer Rate: | 10/100/1000Mbps |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency

Item | Specification |
Installation type | Rack |
Chassis height [U] | 3 U |
Dimensions without packaging (H x W x D) [mm (in.)] | Basic dimensions (excluding the parts protruding from the body): 130.5 mm x 442.0 mm x 470.0 mm (5.14 in. x 17.4 in. x 18.5 in.)Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 130.5 mm x 442.0 mm x 494.7 mm (5.14 in. x 17.4 in. x 19.48 in.) |
Dimensions with packaging (H x W x D) [mm (in.)] | 230 mm x 590 mm x 655 mm (9.06 in. x 23.23 in. x 25.79 in.) |
Weight with packaging [kg (lb)] | 15.77 kg (34.69 lb) |
Weight without packaging [kg (lb)] | 12.5 kg (27.56 lb) |
CPU | 2.2 GHz, 16 cores |
Memory | 8 GB |
NAND Flash | 2 GB |
Console port | RJ45 |
WAN ports | 14 × 10GE (SFP+), 10 × GE copper |
Number of service board slots | 10 |
MIC slots (default/maximum) | 0/0 |
SIC slots (default/maximum) | 4/4 |
WSIC slots (default/maximum) | 2/8 |
XSIC slots (default/maximum) | 4/4 |
RPS input | Not supported |
PoE | Not supported |
IP rating | IP20 |
MTBF [years] | 42.61 years |
MTTR [hours] | 2 hours |
Availability | 0.9999962934 |
Typical power consumption [W] | 126W |
Maximum power consumption [W] | 164W |
Power supply mode | AC/HVDC pluggableDC pluggable |
Number of power modules | 2 |
Rated input voltage [V] | AC rated input voltage range: 100 V to 240 V, 50 Hz/60 Hz |
Input voltage range [V] | AC maximum input voltage range: 90 V to 264 V, 47 Hz to 63 Hz |
Maximum input current [A] | 5 A |
Maximum output power [W] | 350 W |
Redundant power supply | Double AC power modules (1+1 backup)Double DC power modules (1+1 backup) |
Types of fans | Pluggable |
Number of fan modules | 1 |
Heat dissipation mode | Air cooling |
Airflow | Left-to-right airflow |
Noise at normal temperature (acoustic power) [dB(A)] | 66.1 dB(A) |
Long-term operating temperature [°C (°F)] | 0°C to 45°C (32°F to 113°F) NOTE: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m (ft.)] | < 5000 m (16404.2 ft.) |
Storage temperature [°C (°F)] | -40°C to +70°C (-40°F to +158°F) |
Overtemperature alarm | Supported |